DRM SW Advanced Description

The DRM Library has some configuration parameters used to: - Get some status informaton, - Set configuration parmater like timeout, - Customize some behavior.

Warning

Most of these parameters are critical for the system to operate correctly. Any modification without being adviced is at you own risk. Please contact the support team for additional information.

Accessing parameters

There are 2 ways to overwrite the default value of parameters:

  • At start-up, through the DRM Configuration file conf.json: A settings section in the JSON file can be used to list the parameters that must be overwritten. When the object is created, the constructor initialize each parameter in the list with its correpsonding value. This file is managed by the application vendor.

    Parameters from Config JSON file
    {
        "licensing": {
            "url": "https://master.metering.accelize.com"
        },
        "drm": {
            "frequency_mhz": 125
        },
        "design": {
            "boardType": "ISV custom application"
        },
        "settings": {
            "log_verbosity": 1,
            "log_format": "*** [%H:%M:%S %z] [thread %t] %v ***"
        }
    }
    
  • Dynamically from your code, using the get and set functions. Some parameters can be written once by the config file only and can therefore not be modified by these functions.

    C++ get/set functions
    drm_manager_ptr->set<int32_t>( Accelize::DRM::ParameterKey::custom_field, 0x12345678 );    // Set new value to parameter
    int32_t value = drm_manager_ptr->get<int32_t>( Accelize::DRM::ParameterKey::custom_field );  // Get current value of parameter
    
    C get/set functions
    if ( DrmManager_set_int( drm_manager_ptr, Accelize::DRM::DRMParameterKey::custom_field, 0x12345678 ) )
        fprintf( stderr, drm_manager.error_message );
    
    int32_t value;
    if ( DrmManager_get_int( drm_manager_ptr, Accelize::DRM::DRMParameterKey::custom_field, &value ) )
        fprintf( stderr, drm_manager.error_message );
    
    Python get/set functions
    drm_manager.set(custom_field=0x12345678)
    value = drm_manager.get('custom_field')
    

List of parameters

Parameter

Type

Access

Constraint

Description

license_type

string

Read-only

return the license type: node-locked, floating/metering

license_duration

uint32_t

Read-only

return the duration in seconds of the current or last license

num_activators

uint32_t

Read-only

return the number of activators detected by the DRM controller

session_id

string

Read-only

return the current session ID

session_status

bool

Read-only

true or false

indicate if a session is currently open

license_status

bool

Read-only

indicate if a license is running in the Controller

metered_data

uint64_t

Read-only

return the current value of the metering data counter

nodelocked_request_file

string

Read-only

return the path to the node-locked license request JSON file

drm_frequency

int32_t

Read-only

return the measured DRM frequency

drm_license_type

string

Read-only

return the license type of the DRM Controller: node-locked, floating/metering

product_info

string

Read-only

return the product information stored in the DRM Controller Read Only Mailbox

mailbox_size

uint32_t

Read-only

return the size of the Mailbox read-write memory in DRM Controller

token_string

string

Read-only

return the token string

token_validity

uint32_t

Read-only

return the validity in seconds of the current token as provided by the WOAuth2 WS

token_time_left

uint32_t

Read-only

return the number of seconds left until the current token expires

frequency_detection_method

int32_t

Read-only

return the method index used to detect the DRM frequency

bypass_frequency_detection

bool

Read-only

true or false

return true if the frequency detection system is disabled, false otherwise

log_file_path

string

Read-(write)

read (or write) the logging file path: default path is “./drm_lib.log”. Can be set only from configuration file (no override from C/C++ code)

log_file_type

int32_t

Read-(write)

[0-2]

read (or write) the logging file type 0=no logging file, 1=basic file, 2=rotation file. Set only from configuration file (no override from C code)

log_file_rotating_size

int32_t

Read-(write)

read (or write) the logging rotating file size in KBytes: default=1024 (KBytes). Set only from configuration file (no override from C code)

log_file_rotating_num

int32_t

Read-(write)

read (or write) the logging rotating number of backup files: default=3. Set only from configuration file (no override from C code)

log_file_verbosity

int32_t

Read-write

[0-6]

read and write the logging verbosity on the file: 0=trace, 6=quiet

log_file_format

string

Read-write

read and write the logging file format. Refer to spdlog reference manual (https://github.com/gabime/spdlog/wiki/3.-Custom-formatting)

log_verbosity

int32_t

Read-write

[0-6]

read and write the logging verbosity on the stdout/stderr: 0=trace, 6=quiet

log_format

string

Read-write

read and write the logging file format. Refer to spdlog reference manual (https://github.com/gabime/spdlog/wiki/3.-Custom-formatting)

frequency_detection_threshold

double

Read-write

[0.0-100.0]

read and write the accepted percentage of error between the frequency set in the conf file and the measured frequency

frequency_detection_period

uint32_t

Read-write

[100-1000]

read and write the period of time in milliseconds used to measure the real DRM Controller frequency

custom_field

uint32_t

Read-write

only for testing, a register accessible to the user for any purpose

mailbox_data

string

Read-write

32 * mailbox size

only for testing, read or write values to Mailbox read-write memory in DRM Controller

ws_retry_period_long

uint32_t

Read-write

<< license duration

read and write the time in seconds before the next request attempt to the Web Server when the time left before timeout is long

ws_retry_period_short

uint32_t

Read-write

< ws_retry_period_long

read and write the time in seconds before the next request attempt to the Web Server when the time left before timeout is short

ws_request_timeout

uint32_t

Read-write

>0

read and write the web service request timeout in seconds during which the response is waited

log_message_level

int32_t

Read-write

only for testing, read and write the log level used with log_message parameter to set the message level

list_all

string

Read-only

list all parameter keys available

dump_all

string

Read-only

read all parameter key values

page_ctrlreg

string

Read-only

return nothing, print all registers in the DRM Controller Registry page

page_vlnvfile

string

Read-only

return nothing, print all registers in the VLNV File page

page_licfile

string

Read-only

return nothing, print all registers in the License File page

page_tracefile

string

Read-only

return nothing, print all registers in the Trace File page

page_meteringfile

string

Read-only

return nothing, print all registers in the Metering File page

page_mailbox

string

Read-only

return nothing, print all registers in the Mailbox page

hw_report

string

Read-only

return nothing, print the Algodone HW report

trigger_async_callback

string

Write-only

only for testing, call the asynchronous error callback with the given message

log_message

string

Write-only

only for testing, insert a message with the value as content

hdk_compatibility

string

Read-only

only for testing, return the lower version of the HDK it is compatible with

health_period

uint32_t

Read-only

>=0

return the current value of the health period. 0 means the asychronous feature is disabled

health_retry

uint32_t

Read-only

>=0

return the current value of the health retry timeout. 0 means there will be no retry

health_retry_sleep

uint32_t

Read-only

>=0

return the current value of the health retry sleep

ws_api_retry_duration

uint32_t

Read-write

>=0

read and write the period of time in seconds during which retries occur on activate and deactivate functions

host_data_verbosity

uint32_t

Read-(write)

[0:2]

read (and write) the level of verbosity for the amont of host and card data collected. Set only from configuration file (no override from user’s code)

host_data

string

Read-only

read the host and card information

log_file_append

bool

Read-(write)

true or false

read (and write) the appending parameter for the basic logging file. Set only from configuration file (no override from user’s code)

ws_verbosity

uint32_t

Read-(write)

read (and write) the curl verbosity. Set only from configuration file (no override from user’s code)

trng_status

string

Read-only

read the TRNG related status registers

num_license_loaded

uint32_t

Read-only

read the number of licenses provisioned in the DRM Controller

Detailed explanation

Retry mechanism for the license request

There are 2 types of retry mechanisms:

  • One is occurring on the first license request

  • The other one takes place on license request renewal

On the First request

By default a retry mechanism is implemented when the activate function is called.

The retry definition has 2 parameters:

  • ws_retry_period_short: wait period in seconds before a new attempt is performed;

    set to 2s by default

  • ws_request_timeout: period in seconds during which the retry takes place;

    set to 10s by default

Retry on first license request

Note

These parameter values can be changed using the configuration file or the code.

On the other requests

By default a retry mechanism is implemented in the background thread when a new license needs to be renewed.

The retry definition has 2 parameters:

  • ws_retry_period_long: large wait period in seconds before a new attempt is performed;

    set to 60s by default

  • ws_retry_period_short: short wait period in seconds before a new attempt is performed;

    set to 2s by default

The retry period starts when the DRM Controller is ready to receive a new license and lasts until the license expires:

  • The retry periodicity is initially set to ws_retry_period_long until the license expiration time is inferior to ws_retry_period_long

  • Then the retry periodicity is set to ws_retry_period_short until the license expiration occurred.

Retry on license request renewal

Note